Cross-sections · Closed thin-walled sections
Torsional constant It of a rectangular hollow section
Saint-Venant torsional constant calculated using Bredt's first formula: It = 4 · Am² · t / Um.
- General formula, independent of standards
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Width | mm | > 0 | |
| Depth | mm | > 0 | |
| Wall thickness | mm | > 0 | |
| Torsional constant It | cm⁴ | Result |
Valid if
Worked example
= 100 mm · = 150 mm · = 5 mm
= 790.628 cm⁴ · Source: hand calculation: 4 · 95² · 145² · 5 / (2 · 240) = 8148958 mm⁴
Scope and standard
Thin-walled closed rectangular hollow section.
- Result
- in cm⁴
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
- Explain the formulastep by step
- Calculate for my dimensionsenter values, check the result
- Compare with a catalog sectionformula value and table value
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
The search starts in Cross-sections › Closed thin-walled sections.
Miaknows the formula catalog and asks for what is missing.