Actions and loads · Seismic actions

Approximate fundamental period of vibration of building

  • Type: Property
  • Version 1
  • reviewed on 11/13/2026

Approximate fundamental period of vibration for buildings up to 40 m height: T1 = Ct · H⁰.75.

T1=Ct⋅H3/4\displaystyle T_{1} = C_{t} \cdot H^{3/4}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

H

Formula and quantities

SymbolNameUnitNote
Ct\displaystyle C_{t}Building structural type coefficient–Ct\displaystyle C_{t} > 0
H\displaystyle HHeight of building above foundation or rigid basementmH\displaystyle H > 0, ≤ 40
T1\displaystyle T_{1}Fundamental period T_1sResult

Worked example

Ct\displaystyle C_{t} = 0.075 · H\displaystyle H = 16 m

T1\displaystyle T_{1} = 0.6 s · Source: hand calculation

Scope and standard

EN 1998-1, clause 4.3.3.2.2 (C_t = 0.085 steel frames, 0.075 RC frames, 0.050 others).

Standard
EN 1998-1:2004, clause 4.3.3.2.2, Eq. (4.6)
Result
T1\displaystyle T_{1} in s

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
T1\displaystyle T_{1} = 0.6 s= 0.075 · ((16 m) / 1 [m]) ^ 0.75 · 1 [s]

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Actions and loads › Seismic actions.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.