Design · Steel

Base plate effective cantilever projection c

  • Type: Property
  • Version 1
  • reviewed on 11/10/2026

Effective cantilever projection width c of column base plate according to EN 1993-1-8 6.2.5 eq. 6.4: c = t · √(fy / (3 · fjd · γM0)).

c=t⋅fy/(3⋅fjd⋅γM0)\displaystyle c = t \cdot \sqrt{f_{y} / (3 \cdot f_{jd} \cdot \gamma _{\mathrm{M0}})}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

ctfjdfy

Formula and quantities

SymbolNameUnitNote
t\displaystyle tBase plate thicknessmm
fy\displaystyle f_{y}Base plate steel yield strengthN/m²
fjd\displaystyle f_{jd}Design bearing strength of concrete jointN/m²
γM0\displaystyle \gamma_{\mathrm{M0}}Partial factor gamma_M01
c\displaystyle cEffective cantilever projectionmmResult

Worked example

t\displaystyle t = 25 mm · fy\displaystyle f_{y} = 235,000,000 N/m² · fjd\displaystyle f_{jd} = 18,000,000 N/m² · γM0\displaystyle \gamma_{\mathrm{M0}} = 1

c\displaystyle c = 52.15 mm

Standard and source

Result
c\displaystyle c in mm

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
c\displaystyle c = 52.1527 mm= (25 mm) · sqrt((235,000,000 N/m²) / (3 · (18,000,000 N/m²) · (1 1)))

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Steel.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.