Design · Connections
Concentric block tearing resistance Veff,1,Rd
Design block tearing resistance for a bolt group subjected to concentric loading: Veff,1,Rd = fu · Ant / γM2 + (1 / √(3)) · fy · Anv / γM0.
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Ultimate tensile strength of steel plate | N/m² | ||
| Net area subjected to tension | mm² | ||
| Partial factor for fracture of net sections | 1 | ||
| Yield strength of steel plate | N/m² | ||
| Net area subjected to shear | mm² | ||
| Partial factor for cross-section yielding | 1 | ||
| Concentric block tearing resistance | kN | Result |
Worked example
= 510,000,000 N/m² · = 400 mm² · = 1.25 · = 355,000,000 N/m² · = 1,200 mm² · = 1
= 409.15 kN
Standard and source
- Standard
- EN 1993-1-8-2005-ac:2009
- Result
- in kN
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
- Explain the formulastep by step
- Calculate for my memberwith Mia in CALC
- Compare with RFEM/RSTAB resultshand calculation versus model
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
The search starts in Design › Connections.
Miaknows the formula catalog and asks for what is missing.