Structural analysis · Columns and stability

Flexural buckling utilization ratio

  • Type: Property
  • Version 1

Verification utilization ratio of a compression member subjected to axial load: η = NEd / Nb,Rd according to EN 1993-1-1.

η=NEdNb,Rd\displaystyle \eta = \frac{N_{\mathrm{Ed}}}{N_{\mathrm{b},\mathrm{Rd}}}
  • General formula, independent of standards
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

NEdηNb,Rd

Formula and quantities

SymbolNameUnitNote
NEd\displaystyle N_{\mathrm{Ed}}Design axial compression forcekN
Nb,Rd\displaystyle N_{\mathrm{b},\mathrm{Rd}}Buckling resistancekN
η\displaystyle \etaBuckling utilization ratio–Result

Worked example

NEd\displaystyle N_{\mathrm{Ed}} = 850 kN · Nb,Rd\displaystyle N_{\mathrm{b},\mathrm{Rd}} = 1,000 kN

η\displaystyle \eta = 0.85 · Source: 850 / 1000 = 0.85

Scope and standard

Axially loaded compression members, EN 1993-1-1 eq. (6.46).

Result
η\displaystyle \eta (dimensionless)

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
η\displaystyle \eta = 0.85= (850 kN) / (1,000 kN)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Structural analysis › Columns and stability.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.