Structural analysis · Columns and stability
Cross-section compression resistance Nc,Rd
Design resistance of the cross-section for uniform compression: Nc,Rd = (A · fy) / γM0 according to EN 1993-1-1 eq. (6.10).
- General formula, independent of standards
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Cross-sectional area | cm² | ||
| Yield strength | N/m² | ||
| Partial factor for cross-section resistance | – | ||
| Compression resistance | kN | Result |
Worked example
= 53.8 cm² · = 235,000,000 N/m² · = 1
= 1,264.3 kN · Source: 53.8 · 23.5 / 1.0 = 1264.3 kN
Scope and standard
Cross-section classes 1, 2 and 3 in axial compression.
- Result
- in kN
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
- Explain the formulastep by step
- Calculate for my dimensionsenter values, check the result
- Compare with a catalog sectionformula value and table value
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
The search starts in Structural analysis › Columns and stability.
Miaknows the formula catalog and asks for what is missing.