Structural analysis · Columns and stability

Cross-section compression resistance Nc,Rd

  • Type: Property
  • Version 1

Design resistance of the cross-section for uniform compression: Nc,Rd = (A · fy) / γM0 according to EN 1993-1-1 eq. (6.10).

Nc,Rd=A⋅fyγM0\displaystyle N_{\mathrm{c},\mathrm{Rd}} = \frac{A \cdot f_{y}}{\gamma_{\mathrm{M0}}}
  • General formula, independent of standards
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

Nc,Rd

Formula and quantities

SymbolNameUnitNote
A\displaystyle ACross-sectional areacm²
fy\displaystyle f_{y}Yield strengthN/m²
γM0\displaystyle \gamma_{\mathrm{M0}}Partial factor for cross-section resistance–
Nc,Rd\displaystyle N_{\mathrm{c},\mathrm{Rd}}Compression resistancekNResult

Worked example

A\displaystyle A = 53.8 cm² · fy\displaystyle f_{y} = 235,000,000 N/m² · γM0\displaystyle \gamma_{\mathrm{M0}} = 1

Nc,Rd\displaystyle N_{\mathrm{c},\mathrm{Rd}} = 1,264.3 kN · Source: 53.8 · 23.5 / 1.0 = 1264.3 kN

Scope and standard

Cross-section classes 1, 2 and 3 in axial compression.

Result
Nc,Rd\displaystyle N_{\mathrm{c},\mathrm{Rd}} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Nc,Rd\displaystyle N_{\mathrm{c},\mathrm{Rd}} = 1,264.3 kN= ((53.8 cm²) · (235,000,000 N/m²)) / 1

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Structural analysis › Columns and stability.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.