Design · Steel

Lateral-torsional buckling modification factor f

  • Type: Coefficient
  • Version 1
  • reviewed on 11/10/2026

Modification factor f for lateral-torsional buckling for rolled sections according to EN 1993-1-1 6.3.2.3: f = 1 - 0.5 · (1 - kc) · (1 - 2 · (λ̄LT - 0.8)²).

f=1−0.5⋅(1−kc)⋅(1−2⋅(λbar,LT−0.8)2)\displaystyle f = 1 - 0.5 \cdot (1 - k_{\mathrm{c}}) \cdot (1 - 2 \cdot (\lambda _{bar,\mathrm{LT}} - 0.8)^2)
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

λLT

Formula and quantities

SymbolNameUnitNote
kc\displaystyle k_{\mathrm{c}}Correction factor for moment distribution1
λˉLT\displaystyle \bar{\lambda}_{\mathrm{LT}}Non-dimensional slenderness lambda_bar_LT1
f\displaystyle fModification factor f1Result

Worked example

kc\displaystyle k_{\mathrm{c}} = 0.8 · λˉLT\displaystyle \bar{\lambda}_{\mathrm{LT}} = 1

f\displaystyle f = 0.908

Standard and source

Result
f\displaystyle f in 1

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

f\displaystyle f = 0.908 1= 1 - 0.5 · (1 - (0.8 1)) · (1 - 2 · ((1 1) - 0.8)²)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Steel.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.