Design · Connections

Slip resistance of preloaded bolt Fs,Rd

  • Type: Resistance
  • Version 1
  • reviewed on 11/13/2026

Design slip resistance of a preloaded high-strength bolt: Fs,Rd = ks · n · μ · Fp,C / γM3.

Fs,Rd=ks⋅n⋅μ⋅Fp,C/γM3\displaystyle F_{s,\mathrm{Rd}} = k_{s} \cdot n \cdot \mu \cdot F_{p,\mathrm{C}} / \gamma _{M3}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

FsRdFpCμ

Formula and quantities

SymbolNameUnitNote
ks\displaystyle k_{s}Hole type factor (1.0 for normal round holes)1
n\displaystyle nNumber of friction surfaces1
μ\displaystyle \muSlip factor of friction surfaces1
Fp,C\displaystyle F_{p,\mathrm{C}}Nominal preloading forcekN
γM3\displaystyle \gamma_{M3}Partial factor for slip resistance1
Fs,Rd\displaystyle F_{s,\mathrm{Rd}}Design slip resistancekNResult

Worked example

ks\displaystyle k_{s} = 1 · n\displaystyle n = 1 · μ\displaystyle \mu = 0.5 · Fp,C\displaystyle F_{p,\mathrm{C}} = 171.5 kN · γM3\displaystyle \gamma_{M3} = 1.25

Fs,Rd\displaystyle F_{s,\mathrm{Rd}} = 68.6 kN

Standard and source

Result
Fs,Rd\displaystyle F_{s,\mathrm{Rd}} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Fs,Rd\displaystyle F_{s,\mathrm{Rd}} = 68.6 kN= (1 1) · (1 1) · (0.5 1) · (171.5 kN) / (1.25 1)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Connections.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.