Design · Connections
Slip resistance of preloaded bolt Fs,Rd
Design slip resistance of a preloaded high-strength bolt: Fs,Rd = ks · n · μ · Fp,C / γM3.
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Hole type factor (1.0 for normal round holes) | 1 | ||
| Number of friction surfaces | 1 | ||
| Slip factor of friction surfaces | 1 | ||
| Nominal preloading force | kN | ||
| Partial factor for slip resistance | 1 | ||
| Design slip resistance | kN | Result |
Worked example
= 1 · = 1 · = 0.5 · = 171.5 kN · = 1.25
= 68.6 kN
Standard and source
- Standard
- EN 1993-1-8-2005-ac:2009
- Result
- in kN
Reference to clause and equation, no standard text. The description is written in our own words.