Design · Timber

Fastener double shear capacity Mode h Fv,Rk

  • Type: Resistance
  • Version 1
  • reviewed on 11/10/2026

Characteristic load-carrying capacity per shear plane for double shear timber connection Mode h (crushing in middle member) according to EN 1995-1-1 eq. 8.7h: Fv,Rk = 0.5 · fh,2,k · t2 · d.

Fv,Rk=0.5⋅fh,2,k⋅t2⋅d\displaystyle F_{v,Rk} = 0.5 \cdot f_{h,2,k} \cdot t_{2} \cdot d
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

FvRkt2dfh2k

Formula and quantities

SymbolNameUnitNote
fh,2,k\displaystyle f_{h,2,k}Embedment strength in middle memberN/m²
t2\displaystyle t_{2}Middle member thicknessmm
d\displaystyle dFastener diametermm
Fv,Rk\displaystyle F_{v,Rk}Characteristic capacity Mode hkNResult

Worked example

fh,2,k\displaystyle f_{h,2,k} = 24,000,000 N/m² · t2\displaystyle t_{2} = 120 mm · d\displaystyle d = 12 mm

Fv,Rk\displaystyle F_{v,Rk} = 17.28 kN

Standard and source

Result
Fv,Rk\displaystyle F_{v,Rk} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Fv,Rk\displaystyle F_{v,Rk} = 17.28 kN= 0.5 · (24,000,000 N/m²) · (120 mm) · (12 mm)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Timber.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.