Design · Timber

Characteristic load-carrying capacity Johansen mode a Fv,Rk

  • Type: Resistance
  • Version 1
  • reviewed on 11/9/2026

Characteristic shear capacity of a dowel-type fastener in timber-to-timber connection for embedment failure in member 1 (Johansen mode a): Fv,Rk = fh,1,k · t1 · d.

Fv,Rk=fh,1,k⋅t1⋅d\displaystyle F_{v,Rk} = f_{h,1,k} \cdot t_{1} \cdot d
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

Fv,Rkt1dfh,1,k

Formula and quantities

SymbolNameUnitNote
fh,1,k\displaystyle f_{h,1,k}Characteristic embedment strength in member 1N/mm²
t1\displaystyle t_{1}Thickness of timber member 1m
d\displaystyle dFastener diameterm
Fv,Rk\displaystyle F_{v,Rk}Characteristic load-carrying capacity per shear planekNResult

Worked example

fh,1,k\displaystyle f_{h,1,k} = 25 N/mm² · t1\displaystyle t_{1} = 0.06 m · d\displaystyle d = 0.012 m

Fv,Rk\displaystyle F_{v,Rk} = 18 kN · Source: EN 1995-1-1:2004 Eq. (8.6a)

Scope and standard

Single-shear timber-to-timber connections according to EN 1995-1-1, clause 8.2.2.

Standard
EN 1995-1-1:2004, clause 8.2.2 (1), Eq. (8.6a)
Result
Fv,Rk\displaystyle F_{v,Rk} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Fv,Rk\displaystyle F_{v,Rk} = 18 kN= (25 N/mm²) · (0.06 m) · (0.012 m)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Timber.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.