Design · Timber

Nail embedment strength without pre-drilling fh,k (EN 1995-1-1)

  • Type: Property
  • Version 1
  • reviewed on 11/25/2026

Characteristic embedment strength in timber for nails up to 8 mm diameter without pre-drilled holes according to EN 1995-1-1 Clause 8.3.1.1(5) Eq. (8.15): fhk = 0.082 · ρk · d^(-0.3).

fhk=0.082⋅ρk⋅d(−0.3)\displaystyle f_{hk} = 0.082 \cdot \rho _{k} \cdot d^(-0.3)
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

dfhkρk

Formula and quantities

SymbolNameUnitNote
ρk\displaystyle \rho_{k}Characteristic timber densitykg/m³
d\displaystyle dNail diametermm
fhk\displaystyle f_{hk}Characteristic embedment strengthN/m²Result

Worked example

ρk\displaystyle \rho_{k} = 350 kg/m³ · d\displaystyle d = 4 mm

fhk\displaystyle f_{hk} = 18,934,900 N/m²

Standard and source

Result
fhk\displaystyle f_{hk} in MPa

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
fhk\displaystyle f_{hk} = 18,934,900 N/m²= 0.082 · ((350 kg/m³) / 1 [kg/m³]) · ((4 mm) / 1 [mm])^(-0.3) · 1 [MPa]

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Timber.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.