Axially loaded screw withdrawal capacity Fax,alpha,Rk (EN 1995-1-1)
Characteristic withdrawal capacity of a group of axially loaded screws at angle alpha to the grain according to EN 1995-1-1 Clause 8.7.2(4) Eq. (8.38): Fax,Rk = (nef · fax,k · d · lef · kd) / (1.2 · cos(α)² + sin(α)²).
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Effective number of screws | 1 | ||
| Characteristic withdrawal parameter perpendicular to grain | N/m² | ||
| Outer thread diameter of screw | mm | ||
| Effective threaded penetration length | mm | ||
| Diameter correction factor min(d / 8 mm, 1.0) | 1 | ||
| Angle between screw axis and grain direction | ° | ||
| Characteristic screw withdrawal capacity | kN | Result |
Worked example
= 1 · = 11,500,000 N/m² · = 8 mm · = 80 mm · = 1 · = 45 °
= 6.69091 kN
Standard and source
- Standard
- EN 1995-1-1:2004
- Result
- in kN
Reference to clause and equation, no standard text. The description is written in our own words.