Actions and loads · Traffic loads
Reduced railway dynamic factor for earth cover φred (EN 1991-2)
Reduced dynamic factor for railway arch and concrete box bridges with earth cover h > 1.0 m above the crown according to EN 1991-2 Clause 6.4.5.4: φred = φ - (h - 1.0) / 10.
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Unreduced dynamic factor phi_2 or phi_3 | 1 | ||
| Depth of earth cover including ballast in m (> 1.0) | 1 | ||
| Reduced dynamic factor (>= 1.0) | 1 | Result |
Worked examples
2.5 m earth cover
= 1.35 · = 2.5
= 1.2
3.0 m earth cover
= 1.4 · = 3
= 1.2
Standard and source
- Standard
- EN 1991-2:2003, clause 6.4.5.4
- Result
- in 1
Reference to clause and equation, no standard text. The description is written in our own words.