Recommended values or German NA
EN 1992-1-1:2004+AC:2010 with sections 6.5 and Annex J.3 and the recommended values, or with DIN EN 1992-1-1/NA, where J.3 is replaced by the rules of DAfStb Heft 600, Zu J.3.
Privacy settings
We use Microsoft Clarity to understand how CALC is used — only if you agree. Necessary cookies keep the app working (sign-in, security, free-quota enforcement) and are always active.

SKL-000135 · Skill
EN 1992-1-1:2004+AC:2010+A1:2014, 6.2.2, 6.5.2 to 6.5.4, 8.4, Annex J.3DIN EN 1992-1-1/NA:2013-04+A1:2015-12DAfStb Heft 600 (2012), Zu J.3 KonsolenEnter the National Annex, the corbel width and depth, the load position and bearing plate, the concrete and steel, the vertical and horizontal load, and the reinforcement. Mia builds the strut-and-tie model, checks the main tie, the strut and nodes, the bearing pressure, the links, and the anchorage in the corbel and the column, and reports the governing utilization with the clause named.
Mia guides you step by stepShe guides you through the inputs and explains the results.
Check a reinforced concrete corbel to DIN EN 1992-1-1 with the German National Annex: b = 400 mm, hc = 550 mm, ac = 250 mm, bearing plate 200 x 300 x 20 mm, FEd = 600 kN, HEd = 120 kN, C30/37, B500, tie of 4 loops of 16 mm, horizontal links 900 mm².
Values from the calculation code of the skill for the stated inputs with 8 tie legs of 16 mm (4 loops), horizontal links 900 mm², and available anchorage lengths of 420 mm in the corbel and 500 mm in the column. All six checks are satisfied.
These templates prefill the form with typical inputs. They are not calculated results; the calculation runs in CALC.
EN 1992-1-1:2004+AC:2010 with sections 6.5 and Annex J.3 and the recommended values, or with DIN EN 1992-1-1/NA, where J.3 is replaced by the rules of DAfStb Heft 600, Zu J.3.
The model geometry follows from the load position and the compression zone at the column face, with the strut angle limits, the main tie to section 6.5.3, and the strut and node checks to sections 6.5.2 and 6.5.4.
Horizontal or vertical closed links depending on the shear span, and the bearing pressure under the plate as a CCT node to section 6.5.4(4) b).
The anchorage of the tie loops or anchor plate in the corbel and of the tie bars in the column is checked to section 8.4 against the available lengths.
Normative basis
The checks follow these standards. Nationally determined parameters come from the National Annex selected in the form.
Edition used: EN 1992-1-1:2004 + AC:2010
| Country | National Annex | Factors | Source |
|---|---|---|---|
| DE | DIN EN 1992-1-1/NA:2013-04 + DIN EN 1992-1-1/NA/A1:2015-12Current | γC = 1.50γS = 1.15αcc = 0.85 | DIN Media |
Status checked on
Frequently asked questions
EN 1992-1-1:2004+AC:2010 (+A1:2014) with the recommended values or with the German National Annex DIN EN 1992-1-1/NA:2013-04 + NA/A1:2015-12. EN 1992-1-1:2023 and other National Annexes are refused.
The two corbel examples of DAfStb Heft 599, 11.5.1 and 11.5.2, and a university lecture example are recomputed by an automated test; the cases with the recommended values were derived independently and still need a human review.
The German National Annex does not apply Annex J.3. The skill then uses the corbel rules of DAfStb Heft 600, Zu J.3, including the minimum horizontal force HEd of 0.2 FEd.
No. It checks the anchorage of the tie in the column; the column itself is designed with skill 000009-concrete-column-design-ec2.
Start with the example and adapt it to your structural system.
New calculation