Column stability C_P
Slenderness about both axes with K_e from Appendix G, F_cE and C_P per NDS 3.7 with c = 0.8 for sawn lumber and 0.9 for glulam.
Privacy settings
We use Microsoft Clarity to understand how CALC is used — only if you agree. Necessary cookies keep the app working (sign-in, security, free-quota enforcement) and are always active.

SKL-000155 · Skill
ANSI/AWC NDS-2024NDS Supplement 2024ASCE/SEI 7-22Describe the height, end conditions, bracing, the member (sawn lumber or glulam) and the axial and wind loads. Mia applies the NDS adjustment factors, checks compression with column stability, combined bending and compression, shear, bearing and wind deflection in ASD or LRFD, and names the governing check.
Mia guides you step by stepShe guides you through the inputs and explains the results.
Check 2x4 Douglas Fir-Larch No.2 wall studs at 16 in. on center, 10 ft high, pinned at both ends and sheathed, with 300 lb dead and 900 lb snow per stud and 25 psf wind on the wall, to NDS 2024 ASD with an H/180 wind deflection limit.
All values are deterministic for the stated inputs and reproduced by the skill's calculation code with the 2024 NDS Supplement Table 4A values for Douglas Fir-Larch No.2 (Fb = 900 psi, Fc = 1350 psi, Fc⊥ = 625 psi, Emin = 580 000 psi).
These templates prefill the form with typical inputs. They are not calculated results; the calculation runs in CALC.
Slenderness about both axes with K_e from Appendix G, F_cE and C_P per NDS 3.7 with c = 0.8 for sawn lumber and 0.9 for glulam.
Combined bending and compression per NDS 3.9.2 and 15.4 with C_L and the amplification 1 - f_c/F_cE1, for wall studs and eccentric column loads.
Bearing of the stud on the plate with the bearing area factor C_b, and end-grain bearing against F_c*.
All combinations of D, L, Lr, S and W, each with its load duration factor or time effect factor, and the governing one named.
Normative basis
The checks follow these standards. Nationally determined parameters come from the National Annex selected in the form.
Edition used: NDS 2024
Status checked on
Edition used: 2024
Status checked on
Edition used: ASCE 7-22
Status checked on
Frequently asked questions
ANSI/AWC NDS 2024 with the 2024 NDS Supplement design values, and the load combinations of ASCE/SEI 7-22 for ASD and LRFD.
In ASD the combination with wind uses CD = 1.6. In LRFD the combination 1.2D + 1.0S + 0.5W uses the time effect factor lambda = 0.8 of NDS Table N3, so a stud carrying mostly snow with some wind can be more critical in LRFD.
Sheathing fastened to the studs braces their weak axis, so the stud can only buckle about its strong axis (the larger dimension). Without sheathing or blocking, the narrow face usually governs.
Yes. The stud bears perpendicular to the grain of the plate, which often governs for heavily loaded studs. Mia uses the plate's Fc⊥ (the member's unless you give another) with the bearing area factor Cb for a bearing length equal to the stud thickness.
Start with the example and adapt it to your structural system.
New calculation