Dimensionnement · Bois
Contrainte de compression perpendiculaire au fil du bois σc,90,d
Contrainte de calcul à la compression perpendiculaire au fil du bois : σc,90,d = Fc,90,d / Aef.
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Effort de compression de calcul perpendiculaire au fil du bois | kN | ||
| Surface de contact efficace | m² | ||
| Contrainte de calcul à la compression perpendiculaire au fil du bois | N/mm² | Result |
Exemple d’application
= 30 kN · = 0,018 m²
= 1,66667 N/mm² · Source: EN 1995-1-1:2004 Eq. (6.3)
Scope and standard
Appuis et surfaces de contact chargés perpendiculairement au fil du bois selon l'EN 1995-1-1, paragraphe 6.1.5.
- Standard
- EN 1995-1-1:2004, paragraphe 6.1.5 (1), Eq. (6.3)
- Result
- in N/mm²
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
- Explique la formuleétape par étape
- Calculer pour ma barreavec Mia dans CALC
- Comparer avec RFEM/RSTABcalcul à la main vs modèle
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
La recherche commence dans Dimensionnement › Bois.