Resistenza di progetto a taglio per piano di taglio di un rivetto pieno in alluminio secondo EN 1999-1-1 punto 8.5.5 prospetto 8.5: Fv,Rd = 0,6 · fur · A0 / γM2.

Fv,Rd=0.6⋅fur⋅A0/γM2\displaystyle F_{v,\mathrm{Rd}} = 0.6 \cdot f_{ur} \cdot A_{0} / \gamma _{\mathrm{M2}}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

FvRdA0fur

Formula and quantities

SymbolNameUnitNote
fur\displaystyle f_{ur}Resistenza ultima caratteristica a trazione del rivettoN/m²
A0\displaystyle A_{0}Area della sezione trasversale del foro del rivettomm²
γM2\displaystyle \gamma_{\mathrm{M2}}Coefficiente parziale per organi di collegamento (1,25)1
Fv,Rd\displaystyle F_{v,\mathrm{Rd}}Resistenza di progetto a taglio del rivettokNResult

Esempi svolti

10 mm EN AW-5019 rivet

fur\displaystyle f_{ur} = 250.000.000 N/m² · A0\displaystyle A_{0} = 78,54 mm² · γM2\displaystyle \gamma_{\mathrm{M2}} = 1,25

Fv,Rd\displaystyle F_{v,\mathrm{Rd}} = 9,4248 kN

8 mm rivet

fur\displaystyle f_{ur} = 220.000.000 N/m² · A0\displaystyle A_{0} = 50,27 mm² · γM2\displaystyle \gamma_{\mathrm{M2}} = 1,25

Fv,Rd\displaystyle F_{v,\mathrm{Rd}} = 5,30851 kN

Standard and source

Standard
EN 1999-1-1:2007, punto 8.5.5, Eq. Tabella 8.5
Result
Fv,Rd\displaystyle F_{v,\mathrm{Rd}} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Fv,Rd\displaystyle F_{v,\mathrm{Rd}} = 9,4248 kN= 0.6 · (250.000.000 N/m²) · (78,54 mm²) / (1,25 1)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

La ricerca parte in Progetto › Alluminio.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.