Azioni e carichi · Carichi di neve

Coefficiente di forma μ1 del carico di neve per tetto a una falda

  • Tipo: Coefficiente
  • Versione 1
  • revisionata il 06/11/2026

Coefficiente di forma μ1 per neve non accumulata su tetto a una o due falde in funzione della pendenza α, assumendo che la neve possa scivolare dal tetto.

μ1=0.8 for 0°≤α≤30°;0.8⋅(60°−α)/30° for 30°<α<60°;0 for α≥60°\displaystyle μ_{1} = 0.8 \text{ for } 0° ≤ α ≤ 30°; 0.8·(60° − α)/30° \text{ for } 30° < α < 60°; 0 \text{ for } α ≥ 60°

Call in Calculate modemu1_monopitch_ec1(alpha)

Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

μ1α

Formula and quantities

SymbolNameUnitNote
α\displaystyle αPendenza del tetto°
μ1\displaystyle μ_{1}Coefficiente di forma del carico di neve–Result

Esempi svolti

α = 15°

α\displaystyle α = 15 °

μ1\displaystyle μ_{1} = 0,8 · Source: calcolo manuale

α = 45°

α\displaystyle α = 45 °

μ1\displaystyle μ_{1} = 0,4 · Source: calcolo manuale

α = 60°

α\displaystyle α = 60 °

μ1\displaystyle μ_{1} = 0 · Source: calcolo manuale

Scope and standard

Neve non fermata da ostacoli (senza fermaneve o parapetti sulla gronda).

Standard
EN 1991-1-3:2003, punto 5.3.2
Result
μ1\displaystyle μ_{1} (dimensionless)

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
μ1\displaystyle μ_{1} = 0,8= if((15 °) <= 30 [deg]; 0.8; if((15 °) < 60 [deg]; 0.8 · (60 [deg] - (15 °)) / (30 [deg]); 0))

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

La ricerca parte in Azioni e carichi › Carichi di neve.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.