EN 1991-1-7 附属書A.4 式(A.2)に準拠した建物外周保持のための外周水平タイ引張力 Tp = 0.4 · (gk + ψ · qk) · s · L。

Tp=0.4⋅(gk+ψ⋅qk)⋅s⋅L\displaystyle T_{p} = 0.4 \cdot (g_{k} + \psi \cdot q_{k}) \cdot s \cdot L
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

Formula and quantities

SymbolNameUnitNote
gk\displaystyle g_{k}固定荷重特性値kN/m²
ψ\displaystyle \psi組合せ係数–
qk\displaystyle q_{k}積載荷重特性値kN/m²
s\displaystyle s外周柱/タイの間隔m
L\displaystyle L床ベイのスパンm
Tp\displaystyle T_{p}外周タイ引張力kNResult

例題

gk\displaystyle g_{k} = 5 kN/m² · ψ\displaystyle \psi = 0.5 · qk\displaystyle q_{k} = 3 kN/m² · s\displaystyle s = 6 m · L\displaystyle L = 8 m

Tp\displaystyle T_{p} = 124.8 kN

Standard and source

Standard
EN 1991-1-7:2006、付録 A.4項
Result
Tp\displaystyle T_{p} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Tp\displaystyle T_{p} = 124.8 kN= 0.4 · ((5 kN/m²) + 0.5 · (3 kN/m²)) · (6 m) · (8 m)