作用・荷重 · 偶発作用
柱および壁の鉛直タイ力
負担面積 At 上の1層の鉛直固定・積載荷重の最大値に等しい最小鉛直タイ力 Tv: Tv = (gk + ψ · qk) · At。
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 特性固定面荷重 | N/m² | ||
| 偶発設計状況の組合せ係数 | 1 | ||
| 代表値積載面荷重 | N/m² | ||
| 床の負担面積 | m² | ||
| 鉛直タイ力 | kN | Result |
例題
= 6,000 N/m² · = 0.5 · = 3,000 N/m² · = 36 m²
= 270 kN
Standard and source
- Standard
- EN 1991-1-7:2006
- Result
- in kN
Reference to clause and equation, no standard text. The description is written in our own words.