作用・荷重 · 偶発作用

火災区画開口係数 O (EN 1991-1-2)

  • タイプ:特性値
  • バージョン1
  • 2026/11/21にレビュー済み

EN 1991-1-2 附属書A 式(A.4)によるパラメトリック温度時間曲線用の火災区画開口係数 O: O = (Av · √(heq / m)) / At.

O=Av⋅heqAt\displaystyle O = \frac{A_{v} \cdot \sqrt{h_{eq}}}{A_{t}}
  • EN 1991-1-2:2002
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

heq

Formula and quantities

SymbolNameUnitNote
Av\displaystyle A_{v}全壁面の鉛直開口部総面積m²
heq\displaystyle h_{eq}加重平均窓高さm
At\displaystyle A_{t}区画全面積(壁・天井・床、開口部を含む)m²
O\displaystyle O開口係数(m^(1/2))1Result

例題

Av\displaystyle A_{v} = 12 m² · heq\displaystyle h_{eq} = 2 m · At\displaystyle A_{t} = 300 m²

O\displaystyle O = 0.05657 1

Standard and source

Standard
EN 1991-1-2:2002
Result
O\displaystyle O in 1

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
O\displaystyle O = 0.0565685 1= ((12 m²) · sqrt((2 m) / [m])) / (300 m²)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

検索は作用・荷重 › 偶発作用で開始されます。

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.