設計 · 接合部

コンクリートコーンかぶり剥離係数 ψre,N (EN 1992-4)

  • タイプ:特性値
  • バージョン1
  • 2026/11/25にレビュー済み

EN 1992-4 第7.2.1.4項 式(7.5)による密配筋かつ埋込み深さ hef < 100 mm に対するかぶり剥離係数: ψreN = 0.5 + hef / 200.

ψreN=0.5+hef/200\displaystyle \psi _{reN} = 0.5 + h_{\mathrm{ef}} / 200
  • EN 1992-4:2018
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

hefψreN

Formula and quantities

SymbolNameUnitNote
hef\displaystyle h_{\mathrm{ef}}ファスナーの有効埋込み深さmm
ψreN\displaystyle \psi_{reN}かぶり剥離係数1Result

例題

hef\displaystyle h_{\mathrm{ef}} = 70 mm

ψreN\displaystyle \psi_{reN} = 0.85

Standard and source

Standard
EN 1992-4:2018
Result
ψreN\displaystyle \psi_{reN} in 1

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
ψreN\displaystyle \psi_{reN} = 0.85 1= 0.5 + (70 mm) / 200 [mm]