設計 · 接合部
コンクリートコーン縁端応力乱れ係数 ψs,N (EN 1992-4)
EN 1992-4 第7.2.1.4項 式(7.4)による近接縁端によるコンクリート応力分布の乱れを考慮する係数: ψsN = 0.7 + 0.3 · (c / ccrN).
- EN 1992-4:2018
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| ファスナーの最小縁端距離 (c <= c_cr,N) | mm | ||
| 特性縁端距離(通常 1.5 * h_ef) | mm | ||
| 縁端応力乱れ係数 | 1 | Result |
例題
= 100 mm · = 150 mm
= 0.9
Standard and source
- Standard
- EN 1992-4:2018
- Result
- in 1
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
検索は設計 › 接合部で開始されます。
Miaknows the formula catalog and asks for what is missing.