EN 1992-4 第7.2.2.5項 式(7.43)による影響を受けない単一ファスナーの基準コンクリート縁端破壊投影面積: AcV0 = 4.5 · c1².

AcV0=4.5⋅c12\displaystyle A_{cV0} = 4.5 \cdot c_{1}^2
  • EN 1992-4:2018
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

c1AcV0

Formula and quantities

SymbolNameUnitNote
c1\displaystyle c_{1}荷重方向の縁端距離mm
AcV0\displaystyle A_{cV0}基準縁端破壊投影面積mm²Result

例題

c1\displaystyle c_{1} = 100 mm

AcV0\displaystyle A_{cV0} = 45,000 mm²

Standard and source

Standard
EN 1992-4:2018
Result
AcV0\displaystyle A_{cV0} in mm²

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
AcV0\displaystyle A_{cV0} = 45,000 mm²= 4.5 · (100 mm)²