設計 · 接合部
コンクリート縁端破壊基準投影面積 Ac,V0 (EN 1992-4)
EN 1992-4 第7.2.2.5項 式(7.43)による影響を受けない単一ファスナーの基準コンクリート縁端破壊投影面積: AcV0 = 4.5 · c1².
- EN 1992-4:2018
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 荷重方向の縁端距離 | mm | ||
| 基準縁端破壊投影面積 | mm² | Result |
例題
= 100 mm
= 45,000 mm²
Standard and source
- Standard
- EN 1992-4:2018
- Result
- in mm²
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
検索は設計 › 接合部で開始されます。
Miaknows the formula catalog and asks for what is missing.