設計 · 組積造構造
組積造の短期割線弾性係数
特性圧縮強度から推定される組積造の短期割線弾性係数:E = KE · fk。
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 弾性係数比 | – | > 0 | |
| 組積造の特性圧縮強度 | N/mm² | > 0 | |
| 短期弾性係数 | N/mm² | Result |
例題
= 1,000 · = 5 N/mm²
= 5,000 N/mm² · Source: 手計算
Scope and standard
EN 1996-1-1 条項 3.7.2(推奨値 K_E = 1000)。
- Standard
- EN 1996-1-1-2005-a1:2012、3.7.2項、式 (3.7)
- Result
- in N/mm²
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
検索は設計 › 組積造構造で開始されます。
Miaknows the formula catalog and asks for what is missing.