設計 · 組積造構造

せん断を受ける組積造壁の圧縮部長さ

  • タイプ:特性値
  • バージョン1
  • 2026/11/13にレビュー済み

引張強度を無視した線形応力分布による圧縮域長さ:e <= l/6 で lc = l、e > l/6 で lc = 1.5 · (l - 2 · e)。

lc={l,e≤l/61.5⋅(l−2e),e>l/6\displaystyle l_{\mathrm{c}} = \begin{cases} l, & e \le l/6 \\ 1.5 \cdot (l - 2e), & e > l/6 \end{cases}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

yzllc

Formula and quantities

SymbolNameUnitNote
l\displaystyle l壁全長mml\displaystyle l > 0
e\displaystyle e面内荷重偏心 M_Ed / N_Edmme\displaystyle e ≥ 0
lc\displaystyle l_{\mathrm{c}}壁の圧縮長さmmResult

Valid if2⋅e<l\displaystyle 2 \cdot e < l

例題

ひび割れなし断面 e = 300 mm <= 3000/6

l\displaystyle l = 3,000 mm · e\displaystyle e = 300 mm

lc\displaystyle l_{\mathrm{c}} = 3,000 mm · Source: 手計算

ひび割れあり断面 l = 3000 mm, e = 800 mm

l\displaystyle l = 3,000 mm · e\displaystyle e = 800 mm

lc\displaystyle l_{\mathrm{c}} = 2,100 mm · Source: 手計算

Scope and standard

EN 1996-1-1 条項 6.2(2)(e < l / 2 に適用)。

Standard
EN 1996-1-1-2005-a1:2012、6.2項
Result
lc\displaystyle l_{\mathrm{c}} in mm

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
lc\displaystyle l_{\mathrm{c}} = 3,000 mm= if((300 mm) <= (3,000 mm) / 6; (3,000 mm); 1.5 · ((3,000 mm) - 2 · (300 mm)))

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

検索は設計 › 組積造構造で開始されます。

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.