せん断を受ける組積造壁の圧縮部長さ
引張強度を無視した線形応力分布による圧縮域長さ:e <= l/6 で lc = l、e > l/6 で lc = 1.5 · (l - 2 · e)。
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 壁全長 | mm | > 0 | |
| 面内荷重偏心 M_Ed / N_Ed | mm | ≥ 0 | |
| 壁の圧縮長さ | mm | Result |
Valid if
例題
ひび割れなし断面 e = 300 mm <= 3000/6
= 3,000 mm · = 300 mm
= 3,000 mm · Source: 手計算
ひび割れあり断面 l = 3000 mm, e = 800 mm
= 3,000 mm · = 800 mm
= 2,100 mm · Source: 手計算
Scope and standard
EN 1996-1-1 条項 6.2(2)(e < l / 2 に適用)。
- Standard
- EN 1996-1-1-2005-a1:2012、6.2項
- Result
- in mm
Reference to clause and equation, no standard text. The description is written in our own words.