設計 · 組積造構造

組積造壁の有効高さ

  • タイプ:特性値
  • バージョン1
  • 2026/11/13にレビュー済み

階内法高さと拘束低減係数から求まる組積造壁の有効高さ:hef = ρn · h。

hef=ρn⋅h\displaystyle h_{\mathrm{ef}} = \rho_{n} \cdot h
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

hhefρn

Formula and quantities

SymbolNameUnitNote
ρn\displaystyle ρ_{n}有効高さ低減係数(2、3 または 4 辺拘束)–ρn\displaystyle ρ_{n} > 0, ≤ 2
h\displaystyle h壁の階内法高さmh\displaystyle h > 0
hef\displaystyle h_{\mathrm{ef}}壁の有効高さmResult

例題

ρn\displaystyle ρ_{n} = 0.75 · h\displaystyle h = 3 m

hef\displaystyle h_{\mathrm{ef}} = 2.25 m · Source: 手計算

Scope and standard

EN 1996-1-1 条項 5.5.1.2.

Standard
EN 1996-1-1-2005-a1:2012、5.5.1.2項、式 (5.1)
Result
hef\displaystyle h_{\mathrm{ef}} in m

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
hef\displaystyle h_{\mathrm{ef}} = 2.25 m= 0.75 · (3 m)