組積造壁の設計せん断耐力

  • タイプ:耐力
  • バージョン1
  • 2026/11/13にレビュー済み

無筋組積造壁の圧縮部長さに対する設計せん断耐力:VRd = fvd · t · lc。

VRd=fvd⋅t⋅lc\displaystyle V_{\mathrm{Rd}} = f_{vd} \cdot t \cdot l_{\mathrm{c}}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

yzlct

Formula and quantities

SymbolNameUnitNote
fvd\displaystyle f_{vd}組積造の設計せん断強度N/mm²fvd\displaystyle f_{vd} ≥ 0
t\displaystyle t壁厚mmt\displaystyle t > 0
lc\displaystyle l_{\mathrm{c}}壁圧縮部の長さmmlc\displaystyle l_{\mathrm{c}} > 0
VRd\displaystyle V_{\mathrm{Rd}}設計せん断耐力kNResult

例題

fvd\displaystyle f_{vd} = 0.35 N/mm² · t\displaystyle t = 240 mm · lc\displaystyle l_{\mathrm{c}} = 2,500 mm

VRd\displaystyle V_{\mathrm{Rd}} = 210 kN · Source: 手計算

Scope and standard

EN 1996-1-1 条項 6.2 に基づく面内せん断を受ける無筋組積造壁。

Standard
EN 1996-1-1-2005-a1:2012、6.2項、式 (6.13)
Result
VRd\displaystyle V_{\mathrm{Rd}} in kN

Reference to clause and equation, no standard text. The description is written in our own words.