設計 · 接合部
ボルトの押抜きせん断耐力 Bp,Rd
ボルト頭部またはナットの鋼板に対する設計押抜きせん断耐力: Bp,Rd = 0.6 · π · dm · tp · fu / γM2。
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| ボルト頭部またはナットの対角距離と二面幅の平均値 | mm | ||
| ボルト頭部またはナット下の板厚 | mm | ||
| 板の引張強度(最大値) | N/m² | ||
| ボルト接合の部分係数 | 1 | ||
| 押抜きせん断耐力 | kN | Result |
例題
= 32.4 mm · = 8 mm · = 360,000,000 N/m² · = 1.25
= 140.71 kN
Standard and source
- Standard
- EN 1993-1-8-2005-ac:2009
- Result
- in kN
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
検索は設計 › 接合部で開始されます。
Miaknows the formula catalog and asks for what is missing.