鋼構造ピン接合におけるピン1せん断面あたりの設計せん断耐力: Fv,Rd = 0.6 · A · fup / γM2。

Fv,Rd=0.6⋅A⋅fup/γM2\displaystyle F_{v,\mathrm{Rd}} = 0.6 \cdot A \cdot f_{up} / \gamma _{\mathrm{M2}}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

Formula and quantities

SymbolNameUnitNote
A\displaystyle Aピンの断面積mm²
fup\displaystyle f_{up}ピン鋼材の引張強さN/m²
γM2\displaystyle \gamma_{\mathrm{M2}}ピン接合に対する部分係数1
Fv,Rd\displaystyle F_{v,\mathrm{Rd}}ピンの設計せん断耐力kNResult

例題

A\displaystyle A = 1,963.5 mm² · fup\displaystyle f_{up} = 510,000,000 N/m² · γM2\displaystyle \gamma_{\mathrm{M2}} = 1.25

Fv,Rd\displaystyle F_{v,\mathrm{Rd}} = 480.66 kN

Standard and source

Result
Fv,Rd\displaystyle F_{v,\mathrm{Rd}} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Fv,Rd\displaystyle F_{v,\mathrm{Rd}} = 480.665 kN= 0.6 · (1,963.5 mm²) · (510,000,000 N/m²) / (1.25 1)