設計 · 接合部
ピンの設計せん断耐力 Fv,Rd
鋼構造ピン接合におけるピン1せん断面あたりの設計せん断耐力: Fv,Rd = 0.6 · A · fup / γM2。
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| ピンの断面積 | mm² | ||
| ピン鋼材の引張強さ | N/m² | ||
| ピン接合に対する部分係数 | 1 | ||
| ピンの設計せん断耐力 | kN | Result |
例題
= 1,963.5 mm² · = 510,000,000 N/m² · = 1.25
= 480.66 kN
Standard and source
- Standard
- EN 1993-1-8-2005-ac:2009
- Result
- in kN
Reference to clause and equation, no standard text. The description is written in our own words.