設計 · 木構造

木材柱の設計座屈耐力Nc,Rd

  • タイプ:耐力
  • バージョン1
  • 2026/11/9にレビュー済み

木材圧縮部材の設計曲げ座屈耐力: Nc,Rd = kc × A × fc,0,d。

Nc,Rd=kc⋅A⋅fc,0,d\displaystyle N_{\mathrm{c},\mathrm{Rd}} = k_{\mathrm{c}} \cdot A \cdot f_{\mathrm{c},0,\mathrm{d}}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

kcNc,Rd

Formula and quantities

SymbolNameUnitNote
kc\displaystyle k_{\mathrm{c}}座屈低減係数–
A\displaystyle A断面積m²
fc,0,d\displaystyle f_{\mathrm{c},0,\mathrm{d}}繊維方向圧縮設計強度N/mm²
Nc,Rd\displaystyle N_{\mathrm{c},\mathrm{Rd}}設計座屈耐力kNResult

例題

kc\displaystyle k_{\mathrm{c}} = 0.39318 · A\displaystyle A = 0.024 m² · fc,0,d\displaystyle f_{\mathrm{c},0,\mathrm{d}} = 14 N/mm²

Nc,Rd\displaystyle N_{\mathrm{c},\mathrm{Rd}} = 132.108 kN · Source: EN 1995-1-1:2004 式 (6.23)

Scope and standard

EN 1995-1-1 6.3.2項による曲げ座屈を受ける木材圧縮部材。

Standard
EN 1995-1-1:2004、6.3.2 (1)項、式 (6.23)
Result
Nc,Rd\displaystyle N_{\mathrm{c},\mathrm{Rd}} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Nc,Rd\displaystyle N_{\mathrm{c},\mathrm{Rd}} = 132.108 kN= 0.39318 · (0.024 m²) · (14 N/mm²)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

検索は設計 › 木構造で開始されます。

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.