設計 · 木構造
木材柱の設計座屈耐力Nc,Rd
木材圧縮部材の設計曲げ座屈耐力: Nc,Rd = kc × A × fc,0,d。
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 座屈低減係数 | – | ||
| 断面積 | m² | ||
| 繊維方向圧縮設計強度 | N/mm² | ||
| 設計座屈耐力 | kN | Result |
例題
= 0.39318 · = 0.024 m² · = 14 N/mm²
= 132.108 kN · Source: EN 1995-1-1:2004 式 (6.23)
Scope and standard
EN 1995-1-1 6.3.2項による曲げ座屈を受ける木材圧縮部材。
- Standard
- EN 1995-1-1:2004、6.3.2 (1)項、式 (6.23)
- Result
- in kN
Reference to clause and equation, no standard text. The description is written in our own words.