公称炭化深さ dchar,n (EN 1995-1-2)

  • タイプ:特性値
  • バージョン1
  • 2026/11/21にレビュー済み

EN 1995-1-2 第3.4.2項 式(3.2)による角部の丸みおよび割れを考慮した木材の公称炭化深さ: dcharn = βn · t.

dchar,n=βn⋅t\displaystyle d_{\mathrm{char},n} = \beta_{n} \cdot t
  • EN 1995-1-2:2004
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

yzdcharndcharn

Formula and quantities

SymbolNameUnitNote
βn\displaystyle \beta_{n}設計用公称炭化速度(例:集成材 0.70 mm/min)m/s
t\displaystyle t火災加熱時間min
dcharn\displaystyle d_{charn}公称炭化深さmmResult

例題

βn\displaystyle \beta_{n} = 1.16667e-5 m/s · t\displaystyle t = 60 min

dcharn\displaystyle d_{charn} = 42 mm

Standard and source

Standard
EN 1995-1-2:2004
Result
dcharn\displaystyle d_{charn} in mm

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
dcharn\displaystyle d_{charn} = 42.0001 mm= (1.16667e-5 m/s) · (60 min)