設計 · 木構造
4面加熱に対する木材の有効残存断面積 (EN 1995-1-2)
EN 1995-1-2 第4.2.2項による4面加熱長方形木造柱の有効残存断面積: Aef = (b - 2 · def) · (h - 2 · def).
- EN 1995-1-2:2004
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 元の木材断面幅 | mm | ||
| 元の木材断面せい | mm | ||
| 有効炭化深さ | mm | ||
| 有効残存断面積 | mm² | Result |
例題
= 240 mm · = 240 mm · = 49 mm
= 20,164 mm²
Standard and source
- Standard
- EN 1995-1-2:2004
- Result
- in mm²
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
検索は設計 › 木構造で開始されます。
Miaknows the formula catalog and asks for what is missing.