設計 · 複合構造
鋼材寄与率 δ
合成柱の全塑性耐力に対する構造用鋼材の塑性耐力の比(簡易法では 0.2 <= delta <= 0.9):δ = (Aa · fyd) / Npl,Rd。
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 形鋼の断面積 | cm² | ||
| 構造用鋼材の設計降伏強度 | N/m² | ||
| 合成柱の設計塑性耐力 | kN | ||
| 鋼材寄与率 | 1 | Result |
例題
= 118.4 cm² · = 355,000,000 N/m² · = 7,247.3 kN
= 0.58
Standard and source
- Standard
- EN 1994-1-1:2004
- Result
- in 1
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
検索は設計 › 複合構造で開始されます。
Miaknows the formula catalog and asks for what is missing.