鉄筋コンクリート断面の有効深さ
引張鉄筋の重心から圧縮縁までの有効断面深さ:d = h - d1。
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 断面全体の深さ | m | ||
| 引張縁から引張鉄筋重心までの距離 | m | ||
| 断面の有効深さ | m | Result |
例題
= 0.5 m · = 0.05 m
= 0.45 m · Source: 手計算
Scope and standard
引張鉄筋がd_1の深さに配置された鉄筋コンクリート梁、スラブ、柱。
- Standard
- EN 1992-1-1:2004、5.3.2.2項
- Result
- in m
Reference to clause and equation, no standard text. The description is written in our own words.