構造解析 · 動的解析

モード刺激係数

  • タイプ:特性値
  • バージョン1
  • 2026/11/13にレビュー済み

第n次モードのモード刺激係数(モード励起係数を一般化モード質量で除したもの):Γn = Ln / Mn。

Γn=LnMn\displaystyle \Gamma_{n} = \frac{L_{n}}{M_{n}}
  • General formula, independent of standards
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

Formula and quantities

SymbolNameUnitNote
Ln\displaystyle L_{n}モード地震励起係数tLn\displaystyle L_{n} ≥ 0
Mn\displaystyle M_{n}一般化モード質量tMn\displaystyle M_{n} > 0
Γn\displaystyle Γ_{n}モード刺激係数–Result

例題

Ln\displaystyle L_{n} = 850 t · Mn\displaystyle M_{n} = 680 t

Γn\displaystyle Γ_{n} = 1.25 · Source: 手計算

Scope and standard

多自由度系の線形動的解析および応答スペクトル解析。

Result
Γn\displaystyle Γ_{n} (dimensionless)

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Γn\displaystyle Γ_{n} = 1.25= (850 t) / (680 t)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

検索は構造解析 › 動的解析で開始されます。

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.