構造解析 · 動的解析
モード刺激係数
第n次モードのモード刺激係数(モード励起係数を一般化モード質量で除したもの):Γn = Ln / Mn。
- General formula, independent of standards
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| モード地震励起係数 | t | ≥ 0 | |
| 一般化モード質量 | t | > 0 | |
| モード刺激係数 | – | Result |
例題
= 850 t · = 680 t
= 1.25 · Source: 手計算
Scope and standard
多自由度系の線形動的解析および応答スペクトル解析。
- Result
- (dimensionless)
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
検索は構造解析 › 動的解析で開始されます。