構造解析 · 柱と安定性

オイラーケース3(片端固定・片端ピン柱)のオイラー座屈荷重

  • タイプ:特性値
  • バージョン1

一端固定・他端ピン支持柱(オイラーケース3、有効長さ s ≈ 0.699 · l)のオイラー臨界弾性座屈荷重:Ncr = (20.19 · E · I) / l²。

Ncr=20.19⋅E⋅Il2\displaystyle N_{\mathrm{cr}} = \frac{20.19 \cdot E \cdot I}{l^2}
  • General formula, independent of standards
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

Ncrl

Formula and quantities

SymbolNameUnitNote
E\displaystyle E弾性係数N/m²
I\displaystyle I断面二次モーメントcm⁴
l\displaystyle l柱長さm
Ncr\displaystyle N_{\mathrm{cr}}オイラー臨界座屈荷重kNResult

例題

E\displaystyle E = 210,000,000,000 N/m² · I\displaystyle I = 8,356 cm⁴ · l\displaystyle l = 4 m

Ncr\displaystyle N_{\mathrm{cr}} = 22,138 kN · Source: 手計算: 20.19 · 21000 · 8356 / 400² = 22137.95 kN

Scope and standard

オイラーケース3柱(固定-ピン)、弾性座屈。

Result
Ncr\displaystyle N_{\mathrm{cr}} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Ncr\displaystyle N_{\mathrm{cr}} = 22,142.9 kN= (20.19 · (210,000,000,000 N/m²) · (8,356 cm⁴)) / ((4 m)²)