地盤工学 · 土圧

グラウンドアンカーの設計引抜抵抗 Ra,d

  • タイプ:耐力
  • バージョン1
  • 2026/11/12にレビュー済み

注入式グラウンドアンカーの設計引抜抵抗: Rad = Rak / γa。

Ra,d=Ra,kγa\displaystyle R_{a,\mathrm{d}} = \frac{R_{a,k}}{\gamma_{a}}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

Ra,d

Formula and quantities

SymbolNameUnitNote
Ra,k\displaystyle R_{a,k}アンカーの特性引抜抵抗kN
γa\displaystyle \gamma_{a}アンカー引抜抵抗の部分安全係数–
Ra,d\displaystyle R_{a,\mathrm{d}}アンカーの設計引抜抵抗kNResult

例題

Ra,k\displaystyle R_{a,k} = 350 kN · γa\displaystyle \gamma_{a} = 1.1

Ra,d\displaystyle R_{a,\mathrm{d}} = 318.18 kN · Source: EN 1997-1:2004 第8.5.1条

Scope and standard

EN 1997-1第8.5.1項に基づくグラウンドアンカーの設計。

Standard
EN 1997-1:2004、8.5.1項、式 (8.1)
Result
Ra,d\displaystyle R_{a,\mathrm{d}} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Ra,d\displaystyle R_{a,\mathrm{d}} = 318.182 kN= (350 kN) / 1.1

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

検索は地盤工学 › 土圧で開始されます。

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.