断面 · 開放薄肉断面
I形断面のせん断面積 Av,z
ウェブ方向鉛直せん断力 Vz に対するせん断面積:Av,z = h · tw。
- General formula, independent of standards
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| せい | mm | > 0 | |
| ウェブ厚 | mm | > 0 | |
| せん断面積 Av,z | cm² | Result |
例題
= 300 mm · = 8 mm
= 24 cm² · Source: 手計算: 300 · 8 = 2400 mm²
Scope and standard
EN 1993-1-1に準拠した対称圧延または溶接I形断面。
- Result
- in cm²
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
検索は断面 › 開放薄肉断面で開始されます。
Miaknows the formula catalog and asks for what is missing.