小軸 z 周りの塑性断面係数: Wpl,z = (h · b² - (h - 2 · t) · (b - 2 · t)²) / 4.

Wpl,z=h⋅b2−(h−2⋅t)⋅(b−2⋅t)24\displaystyle W_{\mathrm{pl},z} = \frac{h \cdot b^2 - (h - 2 \cdot t) \cdot (b - 2 \cdot t)^2}{4}
  • General formula, independent of standards
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

yzbht

Formula and quantities

SymbolNameUnitNote
b\displaystyle b幅mmb\displaystyle b > 0
h\displaystyle hせいmmh\displaystyle h > 0
t\displaystyle t肉厚mmt\displaystyle t > 0
Wpl,z\displaystyle W_{\mathrm{pl},z}塑性断面係数 Wpl,zcm³Result

Valid if2⋅t<b\displaystyle 2 \cdot t < b2⋅t<h\displaystyle 2 \cdot t < h

例題

b\displaystyle b = 100 mm · h\displaystyle h = 150 mm · t\displaystyle t = 5 mm

Wpl,z\displaystyle W_{\mathrm{pl},z} = 91.5 cm³ · Source: 手計算: (150 · 10000 - 140 · 8100)/4 = 91500 mm³

Scope and standard

矩形中空断面, z軸周りの塑性曲げ

Result
Wpl,z\displaystyle W_{\mathrm{pl},z} in cm³

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Wpl,z\displaystyle W_{\mathrm{pl},z} = 91.5 cm³= ((150 mm) · (100 mm)² - ((150 mm) - 2 · (5 mm)) · ((100 mm) - 2 · (5 mm))²) / 4

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

検索は断面 › 閉鎖薄肉断面で開始されます。

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.