設計 · 鋼構造

局部変形座屈細長比 λd (EN 1993-1-3)

  • タイプ:特性値
  • バージョン1
  • 2026/11/24にレビュー済み

EN 1993-1-3 第5.5.3.1項による補剛要素の局部変形座屈に対する相対細長比: λd = √(fyb / σcr,s).

λd=fyb/σcr,s\displaystyle \lambda _{\mathrm{d}} = \sqrt{f_{yb} / \sigma _{\mathrm{cr},s}}
  • EN 1993-1-3:2006
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

σcr,s

Formula and quantities

SymbolNameUnitNote
fyb\displaystyle f_{yb}基本降伏強度N/m²
σcr,s\displaystyle \sigma_{\mathrm{cr},s}補剛材の弾性座屈応力N/m²
λd\displaystyle \lambda_{\mathrm{d}}局部変形座屈の相対細長比1Result

例題

fyb\displaystyle f_{yb} = 350,000,000 N/m² · σcr,s\displaystyle \sigma_{\mathrm{cr},s} = 280,000,000 N/m²

λd\displaystyle \lambda_{\mathrm{d}} = 1.11803

Standard and source

Standard
EN 1993-1-3:2006
Result
λd\displaystyle \lambda_{\mathrm{d}} in 1

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
λd\displaystyle \lambda_{\mathrm{d}} = 1.11803 1= sqrt((350,000,000 N/m²) / (280,000,000 N/m²))

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

検索は設計 › 鋼構造で開始されます。

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.