設計 · 鋼構造
損傷等価応力範囲 Δσ,E2 (EN 1993-1-9)
EN 1993-1-9 第6.2項による200万回繰返しに換算した損傷等価応力範囲: ΔσE,2 = λeq · Φ2 · Δσp.
- EN 1993-1-9:2005
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 損傷等価係数 | 1 | ||
| 損傷等価動的衝撃係数 | 1 | ||
| 疲労荷重モデルによる基準応力範囲 | N/m² | ||
| 200万回繰返しに対する損傷等価応力範囲 | N/m² | Result |
例題
= 0.85 · = 1.1 · = 75,000,000 N/m²
= 70,125,000 N/m²
Standard and source
- Standard
- EN 1993-1-9:2005
- Result
- in MPa
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
検索は設計 › 鋼構造で開始されます。
Miaknows the formula catalog and asks for what is missing.