設計 · 鋼構造

火災時座屈不整係数 α (EN 1993-1-2)

  • タイプ:特性値
  • バージョン1
  • 2026/11/21にレビュー済み

EN 1993-1-2 第4.2.3.2項 式(4.6)による火災時鋼柱の曲げ座屈不整係数 alpha: α = 0.65 · √(235 / (fy / MPa)).

α=0.65⋅235fy\displaystyle \alpha = 0.65 \cdot \sqrt{\frac{235}{f_{y}}}
  • EN 1993-1-2:2005
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

α

Formula and quantities

SymbolNameUnitNote
fy\displaystyle f_{y}20°C における鋼材の降伏強度N/m²
α\displaystyle \alpha火災時座屈不整係数1Result

例題

fy\displaystyle f_{y} = 355,000,000 N/m²

α\displaystyle \alpha = 0.5289 1

Standard and source

Standard
EN 1993-1-2:2005
Result
α\displaystyle \alpha in 1

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
α\displaystyle \alpha = 0.528851 1= 0.65 · sqrt(235 / ((355,000,000 N/m²) / [MPa]))