設計 · 鋼構造

一縁支持板要素の平板座屈低減係数 ρ (EN 1993-1-5)

  • タイプ:特性値
  • バージョン1
  • 2026/11/24にレビュー済み

EN 1993-1-5 第4.4(2)項による一縁支持圧縮板要素(λp > 0.748)の平板座屈低減係数 rho: ρ = (λp - 0.188) / λp².

ρ=(λp−0.188)/λp2\displaystyle \rho = (\lambda _{p} - 0.188) / \lambda _{p}^2
  • EN 1993-1-5:2006
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

λp

Formula and quantities

SymbolNameUnitNote
λp\displaystyle \lambda_{p}平板の相対細長比1
ρ\displaystyle \rho平板座屈低減係数1Result

例題

λp\displaystyle \lambda_{p} = 1.1

ρ\displaystyle \rho = 0.753719

Standard and source

Standard
EN 1993-1-5:2006
Result
ρ\displaystyle \rho in 1

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

ρ\displaystyle \rho = 0.753719 1= ((1.1 1) - 0.188) / (1.1 1)²

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

検索は設計 › 鋼構造で開始されます。

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.