設計 · 鋼構造

z軸まわりの低減塑性モーメント耐力 MN,z,Rd

  • タイプ:耐力
  • バージョン1
  • 2026/11/10にレビュー済み

EN 1993-1-1 6.2.9.1 式6.38に基づく標準I形断面の軸力を伴うz軸まわりの塑性曲げ耐力:MN,z,Rd = Mpl,z,Rd · (1 - ((n - a) / (1 - a))²)。

MN,z,Rd=Mpl,z,Rd⋅(1−((n−a)/(1−a))2)\displaystyle M_{N,z,\mathrm{Rd}} = M_{\mathrm{pl},z,\mathrm{Rd}} \cdot (1 - ((n - a) / (1 - a))^2)
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

Formula and quantities

SymbolNameUnitNote
Mpl,z,Rd\displaystyle M_{\mathrm{pl},z,\mathrm{Rd}}z軸まわりの塑性モーメント耐力kNm
n\displaystyle n軸力比 N_Ed / N_pl_Rd1
a\displaystyle aウェブ面積比 a1
MN,z,Rd\displaystyle M_{N,z,\mathrm{Rd}}z軸まわりの低減塑性モーメント耐力kNmResult

例題

Mpl,z,Rd\displaystyle M_{\mathrm{pl},z,\mathrm{Rd}} = 80 kNm · n\displaystyle n = 0.5 · a\displaystyle a = 0.25

MN,z,Rd\displaystyle M_{N,z,\mathrm{Rd}} = 71.11 kNm

Standard and source

Result
MN,z,Rd\displaystyle M_{N,z,\mathrm{Rd}} in kNm

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
MN,z,Rd\displaystyle M_{N,z,\mathrm{Rd}} = 71.1111 kNm= (80 kNm) · (1 - (((0.5 1) - (0.25 1)) / (1 - (0.25 1)))²)