構造解析 · 柱と安定性

断面降伏力とオイラー力から求める相対細長比

  • タイプ:特性値
  • バージョン1

鋼材部材の無次元相対細長比:λ̄ = √((A · fy) / Ncr)(EN 1993-1-1による)。

λˉ=A⋅fyNcr\displaystyle \bar{\lambda} = \sqrt{\frac{A \cdot f_{y}}{N_{\mathrm{cr}}}}
  • General formula, independent of standards
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

Ncrλ

Formula and quantities

SymbolNameUnitNote
A\displaystyle A断面積cm²
fy\displaystyle f_{y}降伏強度N/m²
Ncr\displaystyle N_{\mathrm{cr}}オイラー座屈荷重kN
λˉ\displaystyle \bar{\lambda}相対細長比–Result

例題

A\displaystyle A = 53.8 cm² · fy\displaystyle f_{y} = 235,000,000 N/m² · Ncr\displaystyle N_{\mathrm{cr}} = 1,975.5 kN

λˉ\displaystyle \bar{\lambda} = 0.8 · Source: sqrt(53.8 · 23.5 / 1975.5) = sqrt(1264.3 / 1975.5) = 0.80

Scope and standard

EN 1993-1-1による断面等級1、2、3の圧縮材。

Result
λˉ\displaystyle \bar{\lambda} (dimensionless)

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
λˉ\displaystyle \bar{\lambda} = 0.799994= sqrt(((53.8 cm²) · (235,000,000 N/m²)) / (1,975.5 kN))

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

検索は構造解析 › 柱と安定性で開始されます。

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.