設計 · 鋼構造

長パネル a/hw >= 1 のせん断座屈係数 kτ (EN 1993-1-5)

  • タイプ:特性値
  • バージョン1
  • 2026/11/24にレビュー済み

EN 1993-1-5 附属書A.3による横補剛材間隔 a >= hw のウェブパネルに対するせん断座屈係数 ktau: kτ = 5.34 + 4.00 / (a / hw)².

kτ=5.34+4.00/(a/hw)2\displaystyle k_\tau = 5.34 + 4.00 / (a / h_{w})^2
  • EN 1993-1-5:2006
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

hw

Formula and quantities

SymbolNameUnitNote
a\displaystyle a横補剛材間隔mm
hw\displaystyle h_{w}ウェブ内法高さmm
kτ\displaystyle k_\tau せん断座屈係数1Result

例題

a\displaystyle a = 1,500 mm · hw\displaystyle h_{w} = 1,000 mm

kτ\displaystyle k_\tau = 7.11778

Standard and source

Standard
EN 1993-1-5:2006
Result
kτ\displaystyle k_\tau in 1

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
kτ\displaystyle k_\tau = 7.11778 1= 5.34 + 4.0 / ((1,500 mm) / (1,000 mm))²

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

検索は設計 › 鋼構造で開始されます。

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.